Customization: | Available |
---|---|
Application: | Nc Machine Tool |
Speed: | Constant Speed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Min | Typical | Max | Unit |
Input Voltage(DC) | 20 | - | 60 | VDC |
Output current | 0 | - | 8.3 | A |
Pulse Signal Frequency | 0 | - | 200 | KHZ |
Logic Signal Current | 7 | 10 | 16 | MA |
Peak | RMS | SW1 | SW2 | SW3 |
Default | off | off | off | |
3.2A | 2.3A | on | off | off |
4.0A | 2.9A | off | on | off |
4.9A | 3.5A | on | on | off |
5.7A | 4.1A | off | off | on |
6.4A | 4.6A | on | off | on |
7.3A | 5.2A | off | on | on |
8.3A | 5.9A | on | on | on |
Step/Rev | SW5 | SW6 | SW7 | SW8 |
Default | on | on | on | on |
400 | off | on | on | on |
800 | on | off | on | on |
1600 | off | off | on | on |
3200 | on | on | off | on |
6400 | off | on | off | on |
12800 | on | off | off | on |
25600 | off | off | off | on |
1000 | on | on | on | off |
2000 | off | on | on | off |
4000 | on | off | on | off |
5000 | off | off | on | off |
8000 | on | on | off | off |
10000 | off | on | off | off |
20000 | on | off | off | off |
40000 | off | off | off | off |
Control Signal connector | |
Name | Description |
PUL+ | Pulse signal positive |
PUL- | Pulse signal negative |
DIR+ | Direction signal positive |
DIR- | Direction signal negative |
ENA+ | Enable signal positive, usually left unconnected(enable) |
ENA- | Enable signal negative, usually left unconnected(enable) |
GND | Power supply, +24~+90VAC or 20~60 VAC |
+VDC | |
U | Motor phase U |
V | Motor phase V |
W | Motor phase W |
VCC | R |
5V | 0 |
12V | 680Ω |
24V | 1.8KΩ |
problems | Possible cause | solutions |
Motor is not rotating | No power supply | Check the power supply |
No control signal | Check the control signal | |
The driver is disabled | Don't connected the enable signal or enable the driver | |
ALM lights | Supply voltage is too high or too low | Check the supply voltage |
Motor line short-circuit | Check motor lines eliminate the short-circuit | |
Motor line wrong connect | Check the motor wiring | |
Motor or drive failure | Replace the motor or drive | |
Motor rotates in the wrong direction | Motor phases connected in reverse | Reverse the phases line |
Motor line break | Change the phases are connected | |
Inaccurate Position | The Micro steps set incorrectly. | Set the correct segments |
The motor load is too heavy. | Increasing the current | |
Control signal is interfered | Eliminate interference | |
Motor Stalled | Power supply voltage too low | Increasing the supply voltage |
Accelerating time is too short. | Extend the acceleration time | |
Current setting is too small | Increasing the current | |
Motor torque is too small | Replace the motor |