Customization: | Available |
---|---|
Application: | Nc Machine Tool |
Speed: | Constant Speed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Min | Typical | Max | Unit |
Input Voltage(DC) | 24 | 90 | VDC | |
Output Current | 0 | - | 8.2 | A |
Pulse Signal Frequency | 0 | - | 200 | KHZ |
Input Signal Current | 7 | 10 | 16 | mA |
PK current(A) | RMS(A) | SW1 | SW2 | SW3 |
1.8 | 1.29 | 1 | 1 | 1 |
2.7 | 1.93 | 0 | 1 | 1 |
3.6 | 2.57 | 1 | 0 | 1 |
4.6 | 3.29 | 0 | 0 | 1 |
5.5 | 3.93 | 1 | 1 | 0 |
6.4 | 4.57 | 0 | 1 | 0 |
7.3 | 5.21 | 1 | 0 | 0 |
8.2 | 5.86 | 0 | 0 | 0 |
subdivision | SW5 | SW6 | SW7 | SW8 |
400 | 0 | 0 | 0 | 0 |
800 | 1 | 1 | 0 | 0 |
1600 | 0 | 1 | 1 | 0 |
3200 | 1 | 0 | 0 | 1 |
6400 | 1 | 0 | 1 | 1 |
1000 | 0 | 0 | 0 | 1 |
4000 | 0 | 1 | 0 | 1 |
5000 | 1 | 1 | 0 | 1 |
8000 | 0 | 0 | 1 | 1 |
20000 | 0 | 1 | 1 | 1 |
Signal | Function | |
PUL+ | Pulse signal positive | Pulse signal control the motor to run, each pulse make motor running one step. |
PUL- | Pulse signal negative | |
DIR+ | Direction signal positive | Direction control signal to control the direction motor running. |
DIR- | Direction signal negative | |
ENA+ | Enable signal positive, usually left unconnected(enable) | Motor is offline, no internal current enable signal is active. |
ENA- | Enable signal negative, usually left unconnected(enable) |
GND | DC power supply ground |
+VDC | DC power supply positive.+24V~+90VDC. |
A+ | The A phase of two-phase stepper motor |
A- | |
B+ | The B phase of two-phase stepper motor |
B- |