Parameter | Min | Typical | Max | Unit |
Input Voltage(DC) | 60 | - | 110 | VDC |
Input Voltage(AC) | 40 | - | 80 | VAC |
Output current | 0 | - | 7.2 | A |
Pulse Signal Frequency | 0 | - | 200 | KHZ |
Logic Signal Current | 7 | 10 | 16 | MA |
RMS | Peak | SW1 | SW2 | SW3 |
2.00A | 2.40A | on | on | on |
2.57A | 3.08A | off | on | on |
3.14A | 3.77A | on | off | on |
3.71A | 4.45A | off | off | on |
4.28A | 5.14A | on | on | off |
4.86A | 5.83A | off | on | off |
5.43A | 6.52A | on | off | off |
6.00A | 7.20A | off | off | off |
Step/Rev | SW5 | SW6 | SW7 | SW8 |
Default | on | on | on | on |
800 | off | on | on | on |
1600 | on | off | on | on |
3200 | off | off | on | on |
6400 | on | on | off | on |
12800 | off | on | off | on |
25600 | on | off | off | on |
51200 | off | off | off | on |
1000 | on | on | on | off |
2000 | off | on | on | off |
4000 | on | off | on | off |
5000 | off | off | on | off |
8000 | on | on | off | off |
10000 | off | on | off | off |
20000 | on | off | off | off |
40000 | off | off | off | off |
Control Signal connector | |
Name | Description |
DIR- | Direction signal negative |
DIR+ | Direction signal positive |
PUL- | Pulse signal negative |
PUL+ | Pulse signal positive |
ENA- | Enable signal negative, usually left unconnected(enable) |
ENA+ | Enable signal positive, usually left unconnected(enable) |
AC | Power supply +60~+110 VDC or 40V-80VAC |
AC | |
A+ | Motor phase A |
A- | |
B+ | Motor phase B |
B- |
VCC | R |
5V | 0 |
12V | 680Ω |
24V | 1.8KΩ |
problems | Possible cause | solutions |
Motor is not rotating | No power supply | Check the power supply |
No control signal | Check the control signal | |
The driver is disabled | Don't connected the enable signal or enable the driver | |
ALM lights | Supply voltage is too high or too low | Check the supply voltage |
Motor line short-circuit | Check motor lines eliminate the short-circuit | |
Motor line wrong connect | Check the motor wiring | |
Motor or drive failure | Replace the motor or drive | |
Motor rotates in the wrong direction | Motor phases connected in reverse | Reverse the phases line |
Motor line break | Change the phases are connected | |
Inaccurate Position | The Micro steps set incorrectly. | Set the correct segments |
The motor load is too heavy. | Increasing the current | |
Control signal is interfered | Eliminate interference | |
Motor Stalled | Power supply voltage too low | Increasing the supply voltage |
Accelerating time is too short. | Extend the acceleration time | |
Current setting is too small | Increasing the current | |
Motor torque is too small | Replace the motor |