Customization: | Available |
---|---|
Application: | Nc Machine Tool |
Speed: | Constant Speed |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Parameter | Min | Typical | Max | Unit |
Input Voltage(AC) | 150 | - | 220 | VAC |
Output current | 0 | - | 8.3 | A |
Pulse Signal Frequency | 0 | - | 200 | KHZ |
Logic Signal Current | 7 | 10 | 16 | MA |
Phase current | SW5 | SW6 | SW7 | SW8 |
2.0 | 1 | 1 | 1 | 1 |
2.4 | 0 | 1 | 1 | 1 |
2.8 | 1 | 0 | 1 | 1 |
3.2 | 0 | 0 | 1 | 1 |
3.6 | 1 | 1 | 0 | 1 |
4.2 | 0 | 1 | 0 | 1 |
4.8 | 1 | 0 | 0 | 1 |
5.2 | 0 | 0 | 0 | 1 |
5.6 | 1 | 1 | 1 | 0 |
6.0 | 0 | 1 | 1 | 0 |
6.4 | 1 | 0 | 1 | 0 |
6.8 | 0 | 0 | 1 | 0 |
7.2 | 1 | 1 | 0 | 0 |
7.6 | 0 | 1 | 0 | 0 |
8.0 | 1 | 0 | 0 | 0 |
8.3 | 0 | 0 | 0 | 0 |
signal | function |
FAULT- | Common anode input positive terminal Common anode input positive terminal(+5V) |
FAULT+ | |
ENA- | Enable signal terminal motor is offline when Enable signal is active, no internal current. |
ENA+ | |
DIR- | Direction signal terminal Direction control signal control the motor running direction. |
DIR+ | |
PUL- | Pulse signal terminal Pulse signal control the motor to run motor run 1 step after each pulse. |
PUL+ |
AC | Power supply, 150~220VAC |
AC | |
A+ | Motor phase A |
A- | |
B+ | Motor phase B |
B- |